            Hot search:
             

            Transmission Line Steel Pole

            Click on the image to check the artwork
            unit price: negotiable
            min amount:
            amount:
            period for delivery: Consignment Deadline Days
            area: Jiangsu
            Expiry date : Long Effective
            last update: 2018-10-08 01:47
            view count: 393
            enquiry
            Company Profile
             
             
            Product details

            Transmission Line Steel Pole Introduction

            The electric transmission line steel pole has a beautiful appearance. At present, in the wave of building cities and transforming cities, urban construction has higher and higher requirements for power line erection, which is also reflected in the requirements for its aesthetics. In particular, some urban landscape roads have stricter requirements in this respect.

            Because of its compact structure and beautiful appearance, the electric transmission line steel pole can basically meet the requirements of aesthetics.

            Quality galvanized pole cross arm for overhead power line

            Height

            From 8 meter to 55 meter

            Suit for

            Electric Power Transmission and Distribution

            Shape

            Polygonal or Conical

            Material

            Normally Q345B/A572, Minimum Yield Strength ≥ 345 N/mm2
            Q235B/A36, Minimum Yield Strength ≥ 235 N/mm2
            As well as Hot rolled coil from ASTM A572 GR65, GR50, SS400

            Power Capacity

            10kV to 500kV

            Tolerance of the dimension

            According to client’s requirement.

            Surface treatment

            Hot dip galvanized Following ASTM A 123, or any other standard by client required.

            Joint of Poles

            Slip joint, flanged connected

            Standard

            ISO 9001:2008

            Length of per section

            Within 14 meter once forming

            Welding Standard

            AWS (American Welding Society ) D 1.1

            Thickness

            1 mm to 36mm

            Production Process

            Raw material test → Cutting →bending →Welding (longitudinal )→Dimension verify →Flange welding →Hole drilling →sample assemble → surface clean→ Galvanization or powder coating ,painting →Recalibration →Packages

            Packages

            Packing with plastic paper or according to client’s request.


            Product name

            pole cross arm for overhead power line

            Length of per section

            Within 14m once forming without slip joint

            Minimum ultimate tensile strength

            490mpa

            Max ultimate tensile strengt

            620mpa

            Installation way

            The transmission poles below 20 meters are mostly directly buried,?

            more than 20 meters, directly buried with flange installation.?

            85ft above flange installation.

            Power Poles can be classified into:

            (1) Linear poles are widely used in flat areas, accounting for more than 80% of the total number of poles. They are mainly used to support wires, insulators, fittings, and other weights. They can bear lateral wind direction.

            (2) Crossing pole is a kind of linear rod with tension line. It can not only be used for general linear pole, but also prevent large-scale reversing pole, which is used for less important crossing.

            light bearing pole. It is used to prevent conductor breakage after insulator breakdown and is also used for common crossing places.?

            (4) the corner bar is used at the corner of the wire rod to bear the resultant force on both sides of the wire.

            (5) Tension-resistant poles are usually installed at intervals of about 1 km on a line. They can bear the tension of one side of the conductor and can limit the influence of short-line faults.

            (6) the terminal bar is a tensioning pole set at the beginning and end of the line.

            branches and cross poles for 10kV and below. From inside to outside, the branches are T-shaped, and the branches are crossed to the sides.

            Pole longth(m)

            8

            9

            10

            11

            12

            13

            15

            Depth(m)

            1.5

            1.6

            1.7

            1.8

            1.9

            2.0

            2.3

            http://www.futaometal.com/

            Total0bar [View All]  Related Comments
             
            More>other products

            [ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

             
            Home | Products | Suppliers | News | Tradeshow | Sitemap | Message | RSS Feed
             
            欧美特黄AA片在线手机观看
            <label id="beaa5"></label><dd id="beaa5"><track id="beaa5"></track></dd>

            <th id="beaa5"></th>

            <em id="beaa5"><strike id="beaa5"></strike></em>
                  1. <dd id="beaa5"><center id="beaa5"></center></dd>
                    <progress id="beaa5"><big id="beaa5"><noframes id="beaa5"></noframes></big></progress>